ZWD824 Four-Channel Learning RF Remote Decoder IC in SOP-8
Four-channel learning RF remote decoder IC with 7 control modes, 40 remotes of non-volatile memory and EV1527/PT2262 auto-recognition. Decoding, storage, four outputs and LED drive in one SOP-8 package.
Request a quote for this model: info@zowinda.com
Technical specifications
| Package | SOP-8 (150 mil) |
|---|---|
| Output channels | 4 (JQ1–JQ4), active-high, low at power-on |
| Working modes | 7 selectable via learn-key press count, plus clear-code |
| Remote memory | 40 remotes, non-volatile, power-off retention |
| Protocols | EV1527 / SC1527 / PT2240 / PT2262 auto-recognition |
| Supply voltage | DC 2.5 V – 5.5 V |
| Static current | Typ. 2 mA @ 5 V (IC only) |
| Output drive | ≥ 20 mA per channel |
| Operating temperature | -30°C to +75°C |
Protocols & interfaces
Overview
ZWD824 is a self-learning remote-control decoder IC designed for four-channel wireless switching. It integrates RF signal decoding, remote pairing, mode selection, four output channels, key scanning and LED driving on a single silicon die — no firmware to write, no crystal to fit, no external memory to add.
The result is a very small bill of materials: add a standard 315 MHz / 433 MHz receiver module and a handful of passive parts and the remote-control design is complete. It auto-recognises the industry's common encoder families and stores up to 40 remotes, even after power is removed. Only paired remotes respond — unpaired transmitters are simply ignored.

Key features
- Four independent outputs — four active-high channels, each with its own on/off state and LED indication.
- Seven control modes — momentary, toggle, single-select interlock and mixed modes, selected by learn-key press count.
- One-key learning — no programmer, no PC, no tools: press the learn key, then press a remote.
- Up to 40 remotes — pairing data is retained when power is off; relearning overwrites the old slot.
- Auto code detection — works with EV1527, SC1527, PT2240, PT2262 and similar encoders automatically.
- Paired-only response — only learned remotes light the indicator and drive outputs; stray signals do nothing.
- Minimal parts count — no crystal, no external storage; the receiver module connects directly.
- Wide supply range — 2.5 V to 5.5 V operation fits both 3 V and 5 V systems.
How it works
- Connect — wire a 315/433 MHz receiver module to the chip and power it up.
- Choose a mode — short-press the learn key 1–7 times to select the control mode.
- Pair a remote — press any button on the remote; the LED confirms a successful learn.
- Control — press the remote again and the selected output responds instantly.
Pin assignment (SOP-8)

| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | VCC | Power | Positive supply, 2.5–5.5 V; decouple with 0.1 µF close to the pin |
| 2 | JQ1 | Output | Channel 1, active high, maps to remote button A |
| 3 | JQ2 | Output | Channel 2, active high, maps to remote button B |
| 4 | RFIN | Input | RF data input from receiver module DO; weak internal pull-up |
| 5 | JQ3 | Output | Channel 3, active high, maps to remote button C |
| 6 | LE/LED | I/O shared | Learn key and status LED multiplexed |
| 7 | JQ4 | Output | Channel 4, active high, maps to remote button D |
| 8 | GND | Power | Ground |
Pin 6 usage is critical: fit a 20 kΩ pull-down to GND and wire the key to VCC (active high). Never add an external pull-up, or the chip cannot distinguish key presses from LED state.
Seven working modes
Select a mode by short-pressing the learn key. One remote shares one mode across all four buttons. Eight presses clear the learned codes.
| Presses | Mode | Behavior |
|---|---|---|
| 1 | Momentary | Hold the button to switch on; release to switch off |
| 2 | Toggle | Press once to turn on, press again to turn off |
| 3 | Single-select interlock | Only one of four channels is on; another key switches over |
| 4 | Mixed A | Two momentary channels A/B plus two toggle channels C/D |
| 5 | Mixed B | Two momentary channels A/B plus two interlocked channels C/D |
| 6 | Mixed C | Two toggle channels A/B plus two interlocked channels C/D |
| 7 | Dual interlock | Two independent interlocked pairs: A/B and C/D |
| 8 | Clear code | Erase all learned remotes and start over |
MODE 3 is a four-way selector — only one channel on at any time. MODE 7 keeps two independent pairs — each pair interlocks internally, and up to two outputs may be on at once. Choose according to the required interlock scope.
Learning procedure
- Quick-press the learn key N times (1–7 = mode number); each valid press blinks the LED once, with presses inside 2-second intervals.
- Pause about 2 seconds; the LED turns solid, meaning the mode is confirmed and the chip is waiting for a remote.
- Press any button on the remote to pair.
- The LED blinks three times (0.4 s cadence) and exits learning automatically.
- Verify by pressing the paired button — the matching output operates and the LED lights.
Relearning the same remote overwrites its previous mode without consuming another slot. When the 40-remote memory is full, the oldest remote is overwritten. Clearing: 8 quick presses, LED blinks 4 times, memory wipes, then blinks 4 more times when complete.
Electrical parameters
| Item | Value |
|---|---|
| Supply voltage VCC | 2.5–5.5 V (typ. 3.0 V / 5.0 V) |
| Operating temperature | -30°C to +75°C |
| Storage temperature | -40°C to +85°C |
| Static current | Typ. 2 mA @ 5 V (IC only, excluding receiver, LED and loads) |
| Output drive | ≥ 20 mA per channel (LED or transistor base; add drivers for relays) |
Absolute maximum ratings: supply -0.3 V to 6.0 V; any pin -0.3 V to VCC + 0.3 V; junction +85°C max; soldering 260°C / 10 s.
Reference design notes
The English schematic below is the full pin-function circuit for the ZWD824. It shows the minimal SOP-8 application: C3 (104 / 0.1 µF) decouples VCC (pin 1) to GND (pin 8); JQ1–JQ4 (pins 2, 7, 5 and 3) drive four independent LED channels through 3 kΩ resistors and expose button A/B/C/D on a CON4 header; pin 6 combines the learn key S1 and the status LED with an R7 20 kΩ pull-down and an R8 3 kΩ LED6 indicator; and a 480R receiver module feeds RF data into RFIN (pin 4). The mapping to EV1527 / PT2262 encoder pins is printed under the diagram. The receiver module determines the operating frequency — any ready-made 315/433 MHz module can be used, or a matching module can be sourced from us.
- Place the 0.1 µF decoupling capacitor within ~5 mm of pins 1/8; add 100 µF bulk capacitance on VCC to survive receiver current transients.
- Keep the RFIN trace short and away from relay contacts, motor wiring and power switching; reserve a 10–100 kΩ pull-down at RFIN under heavy interference.
- Outputs are logic level only. Drive relays, motors or solenoids through NPN transistors (e.g. S8050), MOSFETs or driver ICs, with freewheeling diodes across inductive loads.
- Antenna: about 17 cm straight wire for 433 MHz, 23 cm for 315 MHz, kept clear of metal and ground planes. Typical open-field range with a good receiver is 30–100 m.
Applications
Remote sockets and strips, multi-zone and classroom/office lighting, alarm panels and wireless triggers, PIR-sensed corridor and street lighting, electric doors, shutters and garage openers, motor forward/reverse and pump/fan/valve switching, wireless paging and identification receivers, and four-channel industrial RF control endpoints.
Ordering information
| Model | Package | Channels | Packing |
|---|---|---|---|
| ZWD824 | SOP-8 | 4 | Tape and reel / tube, by order quantity |
Contact Zowinda Technology Co., Ltd. for samples, volume supply, customized modes or technical support.