ZWD832 Dual-Channel RF Remote Decoder IC — 9 Modes, 30-Code Memory, SOP-8 Plug & Play
Pre-programmed dual-channel independent RF remote decoder IC with EV1527/PT2262 auto-detect, 9 output modes, 30-code EEPROM memory, 2.5–5.5 V supply and a complete reference circuit — no firmware development required.
Request a quote for this model: info@zowinda.com
Technical specifications
| Package | SOP-8 |
|---|---|
| Channels | 2 fully independent (OUT1 / OUT2) |
| Protocols | EV1527 learning code / PT2262 fixed code, automatic recognition |
| Remote memory | 30 remotes (shared pool), EEPROM, power-off retention |
| Output modes | 9 per channel — momentary / toggle / interlock / EV1527 batch / 5 timers |
| Timer options | 10 s / 30 s / 60 s / 180 s / 600 s |
| Supply voltage | DC 2.5–5.5 V (absolute max 2.0–5.5 V) |
| Output drive | ≤ 20 mA per channel; use a transistor/MOSFET for relays |
| RF frequency | Set by external receiver module — 315 / 433.92 / 868 / 915 MHz |
| Operating temperature | -40°C to +85°C |
Protocols & interfaces

Product overview
ZWD832 is a ready-to-use dual-channel wireless remote decoder from Zowinda Technology Co., Ltd. Its firmware is pre-burned at the factory — simply power it up, learn a transmitter, and it works. No coding, no programming and no external MCU. Two fully independent decoder channels, automatic EV1527 / PT2262 recognition, nine selectable output modes and a 30-code memory are all packed into one SOP-8 package.
The two channels are genuinely independent: each learns its own remotes, selects its own output mode and never interferes with the other. Built-in EEPROM stores up to 30 remotes shared across both channels, and learned codes survive power loss permanently.
At a glance
| SOP-8 | 2 | 9 | 30 | 2.5–5.5 V |
|---|---|---|---|---|
| Package | Independent channels | Output modes | Remote slots | Wide supply |
Key features
- True dual-channel — two completely independent outputs. Each channel learns its own remotes and selects its own mode without interfering with the other.
- Auto protocol detect — automatically recognizes EV1527 rolling code and PT2262 fixed code; no manual switching or jumper settings.
- 30-code memory — built-in EEPROM stores up to 30 remotes shared across both channels; learned codes survive power loss permanently.
- Nine output modes — momentary, toggle, interlock, EV1527 batch and five timer options from 10 s to 600 s, selectable by key presses.
- Plug and play — factory-pre-programmed firmware initializes automatically at power-up; learn a remote with a button, no software development.
- Wide voltage range — operates from 2.5 V to 5.5 V DC, compatible with lithium batteries, dry cells and regulated 5 V supplies.
Pin configuration
A compact 8-pin SOP package. Pin 7 (RF) accepts the data output of any superheterodyne or super-regenerative receiver module.
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | VCC | Power | Positive supply, 2.5–5.5 V DC; place a 100 nF bypass capacitor nearby |
| 2 | OUT2 | Output | Channel 2 control output, active high; ≤ 20 mA drive, use a transistor/MOSFET for a relay |
| 3 | LED | Output | Shared status LED output, active high; indicates learn, success and clear states |
| 4 | SET2 | Input | Channel 2 learn / setting key, active low (press to GND) |
| 5 | SET1 | Input | Channel 1 learn / setting key, active low; same behavior as SET2 |
| 6 | OUT1 | Output | Channel 1 control output, active high; same as OUT2 |
| 7 | RF | Input | RF data input (shared), connect to the DO pin of a receiver module; internal pull-up |
| 8 | GND | Ground | Supply ground and common signal reference |
Electrical characteristics
Absolute maximum ratings (Ta = 25°C)
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Supply voltage | VCC | 2.0 ~ 5.5 | V |
| Operating temperature | Topr | −40 ~ +85 | °C |
| Storage temperature | Tstg | −65 ~ +150 | °C |
| I/O pin current | IIO | ±25 | mA |
Recommended operating conditions
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Supply voltage | VCC | 2.5 / 5.0 / 5.5 (min / typ / max) | V |
| RF frequency | fRF | 315 / 433.92 (set by receiver module) | MHz |
| Output high voltage | VOH | VCC × 0.8 | V |
| Output low voltage | VOL | ≤ 0.6 | V |
Nine selectable operating modes
To choose a mode: hold the SET key about 4 seconds to enter learn mode (LED blinks 3 times), then short-press SET the number of times shown below. After about 2 seconds the LED stays on to confirm.
| Presses | Mode | Description |
|---|---|---|
| 1 | Momentary | Output closes while the remote button is held, releases on release — like a doorbell |
| 2 | Toggle (self-lock) | Each press flips the output ON ↔ OFF and holds the state; most widely used |
| 3 | Interlock | Learn an ON key and an OFF key; mutually exclusive, ideal for motor forward/reverse |
| 4 | EV1527 batch | One press learns all four buttons: 1st → 30 s, 2nd → 60 s, 3rd → 180 s, 4th → 600 s (EV1527 only) |
| 5 | Timer 10 s | Trigger closes the output, then automatically opens after 10 seconds |
| 6 | Timer 30 s | Trigger closes the output, then automatically opens after 30 seconds |
| 7 | Timer 60 s | Trigger closes the output, then automatically opens after 60 seconds |
| 8 | Timer 180 s | Trigger closes the output, then automatically opens after 180 seconds |
| 9 | Timer 600 s | Trigger closes the output, then automatically opens after 600 seconds (10 minutes) |
Choosing a mode: the number of short presses on SET equals the mode number (1 momentary / 2 toggle / 3 interlock / 4 batch / 5–9 timer). If unsure, choose mode 2 (toggle) — it behaves just like a normal light switch.
How to learn a remote
All operations are performed on the SET key of the corresponding channel (SET1 for CH1, SET2 for CH2). The two channels never affect each other.
- Hold SET ≈ 4 s — enter learn mode for that channel. LED: solid on → blinks 3×.
- Short-press to select — each press adds 1 to the mode number. LED: 1 blink per press.
- Press remote key — within the 20 s window, press any remote button. LED: blinks 3× = learned.
- Auto exit — the chip returns to standby. Hold SET 4 s again to add another remote (max 30). Timeout: 20 s → 4 blinks.
LED status quick reference
| LED behavior | Meaning |
|---|---|
| Solid while holding SET | Long-press threshold reached (≈ 4 s learn / ≈ 10 s clear) |
| 3 blinks after ≈ 4 s hold | Entered learn mode for that channel |
| 1 blink per short press | Mode number increased by one |
| Solid after mode selected | Mode confirmed, waiting for RF signal (20 s) |
| 3 blinks on RF signal | Learn successful — remote saved |
| 3 blinks then stays on (interlock) | Step 1 done — now press the OFF key |
| 4 blinks after 20 s idle | Learn timed out — nothing saved |
| 4 blinks after ≈ 10 s hold | Clear successful — all remotes erased (both channels) |
Manual toggle without a remote: in normal (non-learn) state, a short press of a SET key flips that channel's output directly — useful when the remote is lost, out of battery, or during installation. Keep the press shorter than 4 seconds to avoid entering learn mode.
Clear all remotes: hold either SET key about 10 seconds until the LED blinks 4 times and goes out. This erases all learned remotes from both channels — use with care. The 30 memory slots are shared, not 15 per channel.
Key timing reference: short press (< 4 s) = manual toggle · hold ≈ 4 s = enter learn · hold ≈ 10 s = clear all. The three thresholds are clearly separated to prevent accidental triggering.
What each mode actually does
① Momentary — hold to act, release to reset. A "press to connect, release to disconnect" switch: hold the remote button and the output closes; let go and it opens instantly. Like a doorbell button. Best for doorbells, sirens, jog relays, electric actuators and pumps that should run only while held.
② Toggle — press once on, press again off. The classic light-switch logic: every press flips the output (ON→OFF, OFF→ON) and the state is retained after release. Like the wall switch at home. Best for lamps, socket switches, roller shutter stop/start — nearly any appliance that must hold its state. The most popular mode.
③ Interlock — one key ON, one key OFF. Requires learning two keys, an ON key and an OFF key. The ON key closes and holds, the OFF key opens; the two are mutually exclusive, so "both on" can never happen. Like an old-style two-button control. Best for motor forward/reverse, electric curtains and sliding gates — anywhere a single state must be guaranteed to prevent short circuits.
④ EV1527 batch — one remote, four timed functions. For EV1527 rolling-code remotes only. Learn with a single key press — the chip picks up all four buttons and binds them to different timers: A (code 0x08) → 30 s, B (0x04) → 60 s, C (0x02) → 180 s, D (0x01) → 600 s. Binding follows the learning order, not the letters printed on the remote. Best for garden lights, exhaust fans and greenhouse ventilation with several timer levels on one remote.
⑤–⑨ Timer — trigger, count down, switch off. One RF trigger closes the output, which then opens automatically after the selected time (10 / 30 / 60 / 180 / 600 s); no second press is needed. Like a corridor sound-activated light that goes dark by itself. Best for stairwell and garage lighting, bathroom extractor fans and hallway lamps — energy saving with five durations.
Frequency and receiver module
The chip decodes digital signals only — the RF frequency is set by the external receiver module. The same firmware works with any frequency; just swap the module.
- 315 MHz — an earlier ISM band with good diffraction through walls; suited to short-range indoor use and legacy remote systems.
- 433.92 MHz (recommended) — worldwide license-free ISM band; mature, low-cost modules with little interference, used by most 1527/2262 remotes.
- Other bands — 868 MHz / 915 MHz also supported, simply fit a matching receiver module; no chip changes required.
Receiver and antenna tips: use a superheterodyne module such as SYN480R, RXB14 or AX5326 for production (better sensitivity and noise immunity); super-regenerative modules suit low-cost, short-range designs. Connect module DO to pin 7 (RF) and share the 2.5–5.5 V supply. A quarter-wave whip antenna (≈ 17 cm at 433 MHz, 23 cm at 315 MHz), kept clear of metal, typically gives 20–80 m open-field range.
Advantage over common alternatives
Most decoding solutions on the market are single-channel learning ICs or custom MCU firmware. ZWD832 is a finished, pre-programmed chip.
| Comparison | Common market solution | ZWD832 |
|---|---|---|
| Channels | Mostly single; dual products share one setting | True dual independent — each learns and configures separately |
| Key binding | One remote controls one channel as a whole | Bind individual remote buttons (A/B/C/D → different functions) |
| Protocol | Fixed to either 2262 or 1527 | EV1527 + PT2262 auto-detect, no switching |
| Output modes | Usually momentary / toggle only | Momentary, toggle, interlock, 5 timers, batch — 9 total |
| Timer options | None or one fixed duration | 5 selectable (10 / 30 / 60 / 180 / 600 s) |
| Memory | Typically 1–15 codes | 30-remote shared pool |
| Ease of use | Requires encoding / programming | Pre-programmed plug & play, learn by button |
| Supply range | Often 5 V only | Wide 2.5–5.5 V — Li-ion, dry cell or 5 V rail |
| Frequency | Fixed | Decoupled from frequency — 315 / 433 / 868 MHz by module |
In short: ZWD832 = dual independent channels + button-level binding + dual protocol + 9 modes + 5 timers + 30-code memory + plug & play. One IC replaces "two single-channel decoders plus a pile of logic" — ideal for dual-channel switches, motor reversing and multi-level timers.
Reference application circuit
A complete typical circuit: RF receiver interface, two transistor-driven relay channels, status LED, setting keys and power decoupling. Values are indicative — adapt them to your design.
Bill of materials
| Ref. | Part | Value / model |
|---|---|---|
| U1 | Decoder IC | ZWD832, SOP-8 |
| M1 | RF receiver | 433 MHz superheterodyne (SYN480R / RXB14) |
| Q1 / Q2 | NPN transistor | S8050, β ≥ 150 |
| J1 / J2 | Relay | 5 V, coil ≥ 100 Ω, SPDT |
| D2 / D3 | Flyback diode | 1N4148 across relay coil |
| D1 | Status LED | Red or green, with 3 kΩ resistor |
| S1 / S2 | Tactile switch | SW-PB, SET1 / SET2, press to GND |
| R1 | Resistor | 3 kΩ — LED current limit |
| R2 / R4 | Resistor | 3 kΩ — Q1 / Q2 base resistor |
| R3 / R5 | Resistor | 10 kΩ — transistor base pull-down |
| C1 | Capacitor | 104 (100 nF) supply decoupling |
| ANT | Antenna | λ/4 whip ≈ 17 cm at 433 MHz |
Layout essentials: place a 100 nF ceramic capacitor close to VCC/GND. Always fit a flyback diode (1N4148 / 1N4007) across each relay coil, cathode toward VCC. Route the receiver DO straight to pin 7 (RF) and keep the antenna away from metal and large copper pours.
Typical applications
- Dual lighting control — one channel drives the main lamp, the other a secondary or ambient light; a single four-button remote controls both, with toggle and timer options.
- Motor forward / reverse — two outputs drive an H-bridge for DC motor reversing, one channel per direction; interlock mode guarantees safety. Ideal for curtain motors, window openers and access gates.
- Smart door access — one channel releases an electric strike in momentary mode, the other drives a doorbell or status indicator; suited to community gates, office locks and parcel lockers.
- Wireless sockets — two outlets controlled independently, each learning its own remote; timer mode enables scheduled shutdown.
- Garage shutter gate — one channel drives the motor open, the other closed; interlock mode prevents both at once. Suitable for garage doors, lifting platforms and electric gates.
- Custom OEM designs — pre-programmed firmware and flexible modes shorten development time for any two-channel RF switching product.
SOP-8 package dimensions
| Parameter | Min (mm) | Typ (mm) | Max (mm) |
|---|---|---|---|
| Package | SOP-8, 8 leads | — | — |
| Body width (A) | 4.80 | 5.00 | 5.20 |
| Body length (D) | 5.80 | 6.00 | 6.20 |
| Lead pitch (e) | 1.27 BSC | — | — |
| Lead width (b) | 0.31 | 0.40 | 0.51 |
| Lead length (L) | 0.40 | 0.60 | 1.27 |
| Overall width (E) | 5.80 | 6.00 | 6.20 |
| Overall length (HE) | 8.65 | 10.00 | 10.35 |
BSC = Basic Spacing between Centers. Specifications are subject to change without notice.