ZWD852 Dual-Channel Learning-Code RF Decoder

SOP-8 dual-channel RF decoder with built-in EV1527 / PT2262 auto-recognition, single-key dual-channel learning, 9 sub-modes per channel and 30-remote EEPROM storage. One chip plus one receiver module completes the whole learn-decode-control chain — no external MCU required.

Technical specifications

Supply voltage2.0 V – 5.5 V
Quiescent current< 5 mA (excluding LED and loads)
Outputs2 independent channels (OUT1 / OUT2)
Operating modesMomentary / Toggle / Interlock / Batch / Delay (10–600 s)
Remote capacityUp to 30 remotes, EEPROM storage
PackageSOP-8 (150 mil)

Protocols & interfaces

EV1527PT2262315 MHz433 MHzLearning code

Overview

ZWD852 integrates RF signal decoding, dual independent output control, EEPROM remote-learning storage, LED status indication and key scanning in a single SOP8 package. Its high-performance decoding engine automatically recognizes EV1527 / PT2262 and other common remote encoding protocols. Together with an external RF receiver module, one chip completes the whole "learn → decode → control" chain — no external MCU needed, which greatly simplifies the BOM and software development.

ZWD852 dual-channel RF decoder chip

ZWD852 provides 2 independent control outputs (OUT1 / OUT2), each configurable with a different operating mode. Because most product enclosures offer only one button position, ZWD852 introduces an innovative single-key dual-channel learning design: a short press on SET1 learns Channel 1, while holding SET1 for about 4 seconds enters Channel 2 learning. One button pairs both channels. SET2 is retained as an optional dedicated pairing key for Channel 2, fully compatible with dual-button enclosures and backward-compatible with ZWD842 operating habits.

Upgrade Path from ZWD842 (Selection Guide)

ItemZWD842ZWD852
Channel 1 learningShort press SET1Short press SET1 (identical)
Channel 2 learningShort press SET2Hold SET1 ≈ 4 seconds, or short press SET2 (retained)
Single-button enclosureNot supportedSupported (SET1 learns both channels)
Outputs / modes / capacityIdentical (2 outputs · 9 sub-modes · 30 remotes)

Package & Pin Assignment

ZWD852 SOP-8 package and pin assignment

PinNameTypeDescription
1VCCPowerPositive supply; place a 104 (0.1 µF) decoupling capacitor nearby
2OUT2OutputChannel 2 control output, active high, drives a transistor directly
3LEDOutputStatus LED output (blinks for learning / pairing / clear events)
4SET2InputChannel 2 pairing / manual key (optional; active low, internal pull-up)
5SET1InputMain pairing key: short press learns CH1, hold ≈ 4 s enters CH2 learning (active low)
6OUT1OutputChannel 1 control output, active high, drives a transistor directly
7RFInputRF data input, connect to the DATA pin of a 315 / 433 MHz receiver module
8GNDPowerGround

Operating Modes & Sub-Mode Selection

ZWD852 offers 4 basic control modes plus 1 batch-learning mode, selectable independently per channel (OUT1 / OUT2). The sub-mode is chosen by the number of short key presses during learning (short presses on SET1 for Channel 1; the same applies to Channel 2 after entering its learning state).

PressesModeNameTypical applications
1×MOMENTARYMomentaryDoorbell, pulse trigger, self-reset buttons
2×TOGGLEToggle (latching)Lamps, power switches, general on/off
3×INTERLOCKInterlock (2-key)Rolling doors, curtains, forward/reverse motors
4×BATCHOne-key learns 4 keys (1527 only)4-output delayed device on one remote (30/60/180/600 s)
5–9×DELAYDelay-off (10/30/60/180/600 s)Stairway lights, exhaust fans, corridor lamps, temporary lighting

Pairing & Learning

Pairing is extremely simple — no programmer or PC is needed. All pairing is done with the on-board keys and a remote right after power-up. Single-button products need only SET1 for the whole process; SET2 is an optional dedicated CH2 pairing key.

ZWD852 single-key dual-channel learning flow

Channel 1 Learning (short press SET1 — same as ZWD842)

  1. From the normal powered state, short press SET1 N times (N = 1–9) to select the sub-mode. Each valid short press is confirmed by one LED blink.
  2. If no further short press occurs within about 2 seconds, the chip confirms the selected mode and the LED stays on ("waiting for remote signal").
  3. Press the corresponding remote key → learning succeeds, the LED blinks 3 times then goes off, and the chip exits learning automatically.

Channel 2 Learning (two ways — choose either)

  • Way A (recommended): hold SET1 for about 4 seconds; when the LED blinks 3 times and goes off, Channel 2 learning is entered. Then short press SET1 N times (N = 1–9) to select the sub-mode exactly as for Channel 1. After about 2 s of inactivity the LED stays on; press the remote key to finish.
  • Way B (optional, retained from ZWD842): short press SET2 N times (N = 1–9) directly to enter Channel 2 learning; the rest is identical.

Both ways are fully equivalent; sub-mode selection and remote-signal waiting behave the same.

Sub-Mode Learning Notes

Sub-modeLearning operation
Momentary / Toggle / Delay (5–9×)With the LED on, press any one key of the remote once — done, LED blinks 3×.
Interlock (3×)Two-step learning: first press one key to learn "ON" (LED blinks 3× then stays on); then press another key of the same remote to learn "OFF" (LED blinks 3× and exits).
Batch (4×, 1527 only)Press any one key of a 1527 remote once; the chip writes key codes 8/4/2/1 automatically (8→30 s, 4→60 s, 2→180 s, 1→600 s), LED blinks 3× to finish.

Exit, Cancel and Timeouts

  • On successful learning (including two-step interlock and 4-key batch) the chip exits learning automatically and the LED goes off.
  • While waiting for the remote signal (LED on), a short press on SET1 cancels learning immediately and returns to normal mode (a short press on SET2 works the same during CH2 learning).
  • During sub-mode selection, about 8 seconds without any press triggers a timeout exit; the LED fast-blinks 4 times.
  • While waiting for the remote signal, about 20 seconds without a valid signal triggers a timeout exit; the LED goes off and normal mode resumes.

Clearing All Remotes

  • Hold SET1 or SET2 for ≥ 10 seconds (works in normal mode or during learning).
  • The LED fast-blinks 4 times to confirm; all learned remotes in EEPROM are erased (both channels).
  • Remotes must be re-learned before use.

LED Indication Summary

LED behaviorMeaning
1 short blinkOne valid short press counted into the sub-mode number
Steady onSub-mode confirmed, waiting for remote signal
3 blinks then off① 4-second hold entered CH2 learning; ② learning succeeded, auto exit
4 fast blinksClear-all completed, or timeout exit during mode selection
Steady on then off (≈20 s)Remote-signal wait timeout, auto exit

Typical Applications

CaseConfiguration & usage
Single-button dual-lamp switch (typical ZWD852 scenario)Enclosure has only 1 button yet controls two lamps: short press SET1 2× to learn OUT1 as Toggle (lamp 1); hold SET1 ≈ 4 s (LED blinks 3×), then short press 2× to learn OUT2 as Toggle (lamp 2). Remote key A → lamp 1 on/off; key B → lamp 2 on/off. Both channels paired through that one button.
Household lamp remote switchToggle mode (2×). OUT1 → transistor → relay coil → lamp circuit. Press key A → lamp on; press again → off.
Stairway / corridor auto-off lightDelay 30 s (6×) or 60 s (7×). One press of any key → lamp on → automatically off after 30/60 s.
Rolling / garage door (interlock)Interlock mode (3×). OUT1 (up) → up relay; OUT2 (down) → down relay. Learn the "up" key then the "down" key; the two keys never interfere.
Doorbell / call buttonMomentary mode (1×). Hold the remote key → OUT1 on → bell rings; release → stop. Also fits security triggers and pulse start/stop.
4 delayed loads on one remote (1527 batch learning)4× enters batch mode; press any one key of a 1527 remote: code 8 → 30 s (stairway lamp), code 4 → 60 s (bathroom exhaust fan), code 2 → 180 s (ventilator), code 1 → 600 s (garage lamp). One remote manages 4 independent delayed loads.

Reference Application Circuit

ZWD852 reference application circuit with dual relay drivers

Circuit composition:

  • Power: VCC is filtered by a 104 ceramic capacitor (C1) and feeds pin 1 VCC; pin 8 GND is grounded.
  • RF receiving: pin 7 RF connects to the DATA output (DO) of a super-heterodyne receiver module (315 MHz / 433 MHz as required). Module VCC to system VCC, module GND to ground.
  • Output drivers: OUT1 / OUT2 (pins 6/2) each drive an S8050 transistor (Q1 / Q2) through a base resistor (R2 / R4, 3K). The transistors switch 5 V relay coils. A 1N4148 flyback diode (D2 / D3) is wired across each coil to protect the transistor from reverse voltage.
  • Manual keys: SET1 (pin 5) / SET2 (pin 4) each connect a tactile switch to GND (internal pull-ups). A pressed key reads low, used for pairing and local manual control; on single-button products SET2 can be omitted and left floating.
  • Status LED: pin 3 LED drives an indicator LED (D1) to GND through R1 (3K). Learning / clear / timeout events are indicated by blinking.

PCB layout tips:

  • Place the VCC decoupling capacitor as close to the chip pin as possible, ideally ≤ 5 mm;
  • Keep the RF trace away from high-current traces (relays, coils); surround it with ground if needed;
  • Never omit the series base resistor of the output transistors (current limiting);
  • Always add a flyback diode (1N4148 / 1N4007) across each relay coil — polarity must not be reversed;
  • Keep the receiver antenna away from metal shielding and high-frequency interference sources.

Key Specifications

ItemValue
Supply voltage2.0 V – 5.5 V
Quiescent current< 5 mA (excluding LED and output loads)
Operating temperature-40 °C – +85 °C
PackageSOP-8 (150 mil)
Output driveOUT pins drive small transistors or LEDs directly; external transistor recommended for relays
Remote capacityUp to 30 remotes (shared address pool across both channels; learning data retained in EEPROM)
ProtocolsEV1527 / PT2262 and other common remote encodings (auto-recognized)
Interference immunityA frame is accepted only when two consecutive decoded frames match exactly; every learning write is read back and verified
RF frequencyDetermined by the external receiver module (315 MHz / 433 MHz ISM bands, etc.)

Note: for absolute maximum ratings and detailed electrical characteristics, please refer to the full datasheet or contact Zowinda Technology Co., Ltd. technical support.

Back to catalog