ZWD852 Dual-Channel Learning-Code RF Decoder
SOP-8 dual-channel RF decoder with built-in EV1527 / PT2262 auto-recognition, single-key dual-channel learning, 9 sub-modes per channel and 30-remote EEPROM storage. One chip plus one receiver module completes the whole learn-decode-control chain — no external MCU required.
Request a quote for this model: info@zowinda.com
Technical specifications
| Supply voltage | 2.0 V – 5.5 V |
|---|---|
| Quiescent current | < 5 mA (excluding LED and loads) |
| Outputs | 2 independent channels (OUT1 / OUT2) |
| Operating modes | Momentary / Toggle / Interlock / Batch / Delay (10–600 s) |
| Remote capacity | Up to 30 remotes, EEPROM storage |
| Package | SOP-8 (150 mil) |
Protocols & interfaces
Overview
ZWD852 integrates RF signal decoding, dual independent output control, EEPROM remote-learning storage, LED status indication and key scanning in a single SOP8 package. Its high-performance decoding engine automatically recognizes EV1527 / PT2262 and other common remote encoding protocols. Together with an external RF receiver module, one chip completes the whole "learn → decode → control" chain — no external MCU needed, which greatly simplifies the BOM and software development.

ZWD852 provides 2 independent control outputs (OUT1 / OUT2), each configurable with a different operating mode. Because most product enclosures offer only one button position, ZWD852 introduces an innovative single-key dual-channel learning design: a short press on SET1 learns Channel 1, while holding SET1 for about 4 seconds enters Channel 2 learning. One button pairs both channels. SET2 is retained as an optional dedicated pairing key for Channel 2, fully compatible with dual-button enclosures and backward-compatible with ZWD842 operating habits.
Upgrade Path from ZWD842 (Selection Guide)
| Item | ZWD842 | ZWD852 |
|---|---|---|
| Channel 1 learning | Short press SET1 | Short press SET1 (identical) |
| Channel 2 learning | Short press SET2 | Hold SET1 ≈ 4 seconds, or short press SET2 (retained) |
| Single-button enclosure | Not supported | Supported (SET1 learns both channels) |
| Outputs / modes / capacity | Identical (2 outputs · 9 sub-modes · 30 remotes) |
Package & Pin Assignment
| Pin | Name | Type | Description |
|---|---|---|---|
| 1 | VCC | Power | Positive supply; place a 104 (0.1 µF) decoupling capacitor nearby |
| 2 | OUT2 | Output | Channel 2 control output, active high, drives a transistor directly |
| 3 | LED | Output | Status LED output (blinks for learning / pairing / clear events) |
| 4 | SET2 | Input | Channel 2 pairing / manual key (optional; active low, internal pull-up) |
| 5 | SET1 | Input | Main pairing key: short press learns CH1, hold ≈ 4 s enters CH2 learning (active low) |
| 6 | OUT1 | Output | Channel 1 control output, active high, drives a transistor directly |
| 7 | RF | Input | RF data input, connect to the DATA pin of a 315 / 433 MHz receiver module |
| 8 | GND | Power | Ground |
Operating Modes & Sub-Mode Selection
ZWD852 offers 4 basic control modes plus 1 batch-learning mode, selectable independently per channel (OUT1 / OUT2). The sub-mode is chosen by the number of short key presses during learning (short presses on SET1 for Channel 1; the same applies to Channel 2 after entering its learning state).
| Presses | Mode | Name | Typical applications |
|---|---|---|---|
| 1× | MOMENTARY | Momentary | Doorbell, pulse trigger, self-reset buttons |
| 2× | TOGGLE | Toggle (latching) | Lamps, power switches, general on/off |
| 3× | INTERLOCK | Interlock (2-key) | Rolling doors, curtains, forward/reverse motors |
| 4× | BATCH | One-key learns 4 keys (1527 only) | 4-output delayed device on one remote (30/60/180/600 s) |
| 5–9× | DELAY | Delay-off (10/30/60/180/600 s) | Stairway lights, exhaust fans, corridor lamps, temporary lighting |
Pairing & Learning
Pairing is extremely simple — no programmer or PC is needed. All pairing is done with the on-board keys and a remote right after power-up. Single-button products need only SET1 for the whole process; SET2 is an optional dedicated CH2 pairing key.
Channel 1 Learning (short press SET1 — same as ZWD842)
- From the normal powered state, short press SET1 N times (N = 1–9) to select the sub-mode. Each valid short press is confirmed by one LED blink.
- If no further short press occurs within about 2 seconds, the chip confirms the selected mode and the LED stays on ("waiting for remote signal").
- Press the corresponding remote key → learning succeeds, the LED blinks 3 times then goes off, and the chip exits learning automatically.
Channel 2 Learning (two ways — choose either)
- Way A (recommended): hold SET1 for about 4 seconds; when the LED blinks 3 times and goes off, Channel 2 learning is entered. Then short press SET1 N times (N = 1–9) to select the sub-mode exactly as for Channel 1. After about 2 s of inactivity the LED stays on; press the remote key to finish.
- Way B (optional, retained from ZWD842): short press SET2 N times (N = 1–9) directly to enter Channel 2 learning; the rest is identical.
Both ways are fully equivalent; sub-mode selection and remote-signal waiting behave the same.
Sub-Mode Learning Notes
| Sub-mode | Learning operation |
|---|---|
| Momentary / Toggle / Delay (5–9×) | With the LED on, press any one key of the remote once — done, LED blinks 3×. |
| Interlock (3×) | Two-step learning: first press one key to learn "ON" (LED blinks 3× then stays on); then press another key of the same remote to learn "OFF" (LED blinks 3× and exits). |
| Batch (4×, 1527 only) | Press any one key of a 1527 remote once; the chip writes key codes 8/4/2/1 automatically (8→30 s, 4→60 s, 2→180 s, 1→600 s), LED blinks 3× to finish. |
Exit, Cancel and Timeouts
- On successful learning (including two-step interlock and 4-key batch) the chip exits learning automatically and the LED goes off.
- While waiting for the remote signal (LED on), a short press on SET1 cancels learning immediately and returns to normal mode (a short press on SET2 works the same during CH2 learning).
- During sub-mode selection, about 8 seconds without any press triggers a timeout exit; the LED fast-blinks 4 times.
- While waiting for the remote signal, about 20 seconds without a valid signal triggers a timeout exit; the LED goes off and normal mode resumes.
Clearing All Remotes
- Hold SET1 or SET2 for ≥ 10 seconds (works in normal mode or during learning).
- The LED fast-blinks 4 times to confirm; all learned remotes in EEPROM are erased (both channels).
- Remotes must be re-learned before use.
LED Indication Summary
| LED behavior | Meaning |
|---|---|
| 1 short blink | One valid short press counted into the sub-mode number |
| Steady on | Sub-mode confirmed, waiting for remote signal |
| 3 blinks then off | ① 4-second hold entered CH2 learning; ② learning succeeded, auto exit |
| 4 fast blinks | Clear-all completed, or timeout exit during mode selection |
| Steady on then off (≈20 s) | Remote-signal wait timeout, auto exit |
Typical Applications
| Case | Configuration & usage |
|---|---|
| Single-button dual-lamp switch (typical ZWD852 scenario) | Enclosure has only 1 button yet controls two lamps: short press SET1 2× to learn OUT1 as Toggle (lamp 1); hold SET1 ≈ 4 s (LED blinks 3×), then short press 2× to learn OUT2 as Toggle (lamp 2). Remote key A → lamp 1 on/off; key B → lamp 2 on/off. Both channels paired through that one button. |
| Household lamp remote switch | Toggle mode (2×). OUT1 → transistor → relay coil → lamp circuit. Press key A → lamp on; press again → off. |
| Stairway / corridor auto-off light | Delay 30 s (6×) or 60 s (7×). One press of any key → lamp on → automatically off after 30/60 s. |
| Rolling / garage door (interlock) | Interlock mode (3×). OUT1 (up) → up relay; OUT2 (down) → down relay. Learn the "up" key then the "down" key; the two keys never interfere. |
| Doorbell / call button | Momentary mode (1×). Hold the remote key → OUT1 on → bell rings; release → stop. Also fits security triggers and pulse start/stop. |
| 4 delayed loads on one remote (1527 batch learning) | 4× enters batch mode; press any one key of a 1527 remote: code 8 → 30 s (stairway lamp), code 4 → 60 s (bathroom exhaust fan), code 2 → 180 s (ventilator), code 1 → 600 s (garage lamp). One remote manages 4 independent delayed loads. |
Reference Application Circuit
Circuit composition:
- Power: VCC is filtered by a 104 ceramic capacitor (C1) and feeds pin 1 VCC; pin 8 GND is grounded.
- RF receiving: pin 7 RF connects to the DATA output (DO) of a super-heterodyne receiver module (315 MHz / 433 MHz as required). Module VCC to system VCC, module GND to ground.
- Output drivers: OUT1 / OUT2 (pins 6/2) each drive an S8050 transistor (Q1 / Q2) through a base resistor (R2 / R4, 3K). The transistors switch 5 V relay coils. A 1N4148 flyback diode (D2 / D3) is wired across each coil to protect the transistor from reverse voltage.
- Manual keys: SET1 (pin 5) / SET2 (pin 4) each connect a tactile switch to GND (internal pull-ups). A pressed key reads low, used for pairing and local manual control; on single-button products SET2 can be omitted and left floating.
- Status LED: pin 3 LED drives an indicator LED (D1) to GND through R1 (3K). Learning / clear / timeout events are indicated by blinking.
PCB layout tips:
- Place the VCC decoupling capacitor as close to the chip pin as possible, ideally ≤ 5 mm;
- Keep the RF trace away from high-current traces (relays, coils); surround it with ground if needed;
- Never omit the series base resistor of the output transistors (current limiting);
- Always add a flyback diode (1N4148 / 1N4007) across each relay coil — polarity must not be reversed;
- Keep the receiver antenna away from metal shielding and high-frequency interference sources.
Key Specifications
| Item | Value |
|---|---|
| Supply voltage | 2.0 V – 5.5 V |
| Quiescent current | < 5 mA (excluding LED and output loads) |
| Operating temperature | -40 °C – +85 °C |
| Package | SOP-8 (150 mil) |
| Output drive | OUT pins drive small transistors or LEDs directly; external transistor recommended for relays |
| Remote capacity | Up to 30 remotes (shared address pool across both channels; learning data retained in EEPROM) |
| Protocols | EV1527 / PT2262 and other common remote encodings (auto-recognized) |
| Interference immunity | A frame is accepted only when two consecutive decoded frames match exactly; every learning write is read back and verified |
| RF frequency | Determined by the external receiver module (315 MHz / 433 MHz ISM bands, etc.) |
Note: for absolute maximum ratings and detailed electrical characteristics, please refer to the full datasheet or contact Zowinda Technology Co., Ltd. technical support.